Features
- Un-limited load applicability
- Un-limited batteries backup time
- 24 hours operation on the Inverter
- Multi-stage charger supports batteries up to 600AH.
- Compatible with both linear & non-linear load.
- Controllable & Removable panel with LCD
- Parameter Pre-settable
- Support solar panel
- Low DC Voltage supports Office and Home appliances
- DC start and automatic self-diagnostic function
- High efficiency design to save electricity
- Low heat dissipation in long time operation.
- Designed to operate under harsh environment
- Optional Multiple interfaces cards available.
Overview
The Vesta series provides comprehensive protection and high power density in small and economic package. Compared to traditional UPS towers of the same size, Vesta UPS is more compact and offers greater comprehensive power protection against surges and spikes. Equipped with a voltage stabilizer, this UPS will continue providing clean and stable power to connected equipment while its embedded microprocessor controller guarantees high reliability, perfect for any home or small office applicatio
|
Model |
AHS-243 |
AHS-363 |
Capacity |
VA / Watt |
2.4KVA/1600W |
3.6KVA/2400W |
Input |
Nominal Voltage |
110/115/120Vac or 220/230/240Vac |
Voltage Range |
Acceptable Voltage Range |
60~135Vac or 120~270Vac |
Frequency |
45Hz ~ 70Hz Auto-sensing |
Low Voltage Transfer |
60Vac+/-2% ; 120Vac+/-2% |
Low Voltage Return |
65Vac+/-2% ; 130Vac+/-2% |
High Voltage Transfer |
135Vac+/-2% ; 270Vac+/-2% |
High Voltage Return |
130Vac+/-2% ; 260Vac+/-2% |
Output |
Voltage |
|
110/115/120Vac or 220/230/240Vac re-settable via LCD panel |
Voltage Regulation(Bat. Mode) |
<3% RMS for entire battery voltage range |
Frequency Regulation |
Line Mode |
Synchronized to AC Main |
Battery Mode |
50Hz or 60Hz 0.1Hz |
Power Factor |
0.67 |
Wave Form |
Pure Sine wave |
Effeciency |
>80% |
Overload Protection |
Line Mode |
>110%,then Buzzer Alarm and Amber LED Blink Continuously. |
Battery Mode |
110%~150% for 30 sec; >150% for 200ms, then UPS Shuts Down |
Short Circuit Protection |
Line Mode |
Circuit Breaker |
Battery Mode |
Electronic Circuit |
DC Start |
Cold Start |
Yes |
Transfer Time |
Typical |
< 8 ms. |
Battery |
Battery Voltage |
24Vdc |
Backup Time |
the batteries connected |
Recharging Current |
>50A |
Control Panel |
LCD Display |
UPS status, I/P&O/P Voltage Frequency, Load Level,
Battery Voltage & Level, Temperature, Model |
LED Display |
Normal (Green), Warning (Amber), Fault (Red) |
Audible Alarm |
Battery Mode |
Beeping every 4 seconds |
Low Battery |
Beeping every second |
UPS Fault |
Beeping twice per second |
Overload |
Beeping twice per second |
Parameter Re-settable |
Voltage,Frequency,5 steps Charge current |
Environment |
Operation Temperature |
0-40 degree C; 32-104 degree F |
Relative Humidity |
0-95% non-condensing |
Audible Noise |
Less than 55dBA (at 1M) |
Physical |
Wall Mounted Type(W*H*D)mm |
298*450*190 |
298*450*190 |
Wall Mounted Type Net Weight (Kgs) |
23.0 |
24.2 |
Safety Conformance |
Safety Standard |
|
EN62040-1-1 |
EMC |
EN62040-2 |
Marks |
CE |