ProdcutLines

  • Options

Inverter AHS-123

big_pic

Features

  • Un-limited load applicability
  • Un-limited batteries backup time
  • 24 hours operation on the Inverter
  • Multi-stage charger supports batteries up to 600AH.
  • Compatible with both linear & non-linear load.
  • Controllable & Removable panel with LCD
  • Parameter Pre-settable
  • Support solar panel
  • Low DC Voltage supports Office and Home appliances
  • DC start and automatic self-diagnostic function
  • High efficiency design to save electricity
  • Low heat dissipation in long time operation.
  • Designed to operate under harsh environment
  • Optional Multiple interfaces cards available.

Overview

The Vesta series provides comprehensive protection and high power density in small and economic package. Compared to traditional UPS towers of the same size, Vesta UPS is more compact and offers greater comprehensive power protection against surges and spikes. Equipped with a voltage stabilizer, this UPS will continue providing clean and stable power to connected equipment while its embedded microprocessor controller guarantees high reliability, perfect for any home or small office applicatio
Specifications

Model

AHS-123

Capacity

VA / Watt

1.2KVA/800W

 Input

 Nominal Voltage

 110/115/120Vac or 220/230/240Vac

 Voltage Range

 Acceptable Voltage Range

 60~135Vac or 120~270Vac

 Frequency

45Hz ~ 70Hz Auto-sensing

 Low Voltage Transfer

 60Vac+/-2% ; 120Vac+/-2%

 Low Voltage Return

 65Vac+/-2% ; 130Vac+/-2%

 High Voltage Transfer

 135Vac+/-2% ; 270Vac+/-2%

 High Voltage Return

 130Vac+/-2% ; 260Vac+/-2%

 Output

 Voltage

 

 110/115/120Vac or 220/230/240Vac re-settable via LCD panel

 Voltage Regulation(Bat. Mode)

 <3% RMS for entire battery voltage range

 Frequency Regulation

Line Mode

 Synchronized to AC Main

Battery Mode

50Hz or 60Hz  ±0.1Hz

Power Factor

0.67

 Wave Form

Pure Sine wave

 Effeciency

>75%

 Overload Protection

Line Mode

>110%,then Buzzer Alarm and Amber LED Blink Continuously.

Battery Mode

110%~150% for 30 sec; >150% for 200ms, then UPS Shuts Down

 Short Circuit Protection

Line Mode

Circuit Breaker

Battery Mode

Electronic Circuit

 DC Start

 Cold Start

Yes

Transfer Time

Typical

< 8 ms.

 Battery

 Battery Voltage

 12Vdc

Backup Time

Base on

Recharging Current

>40A

 Control Panel

LCD Display

UPS status, I/P&O/P Voltage Frequency, Load Level,
Battery Voltage & Level,  Temperature, Model

LED Display

Normal (Green), Warning (Amber), Fault (Red)

 Audible Alarm

Battery  Mode

Beeping every 4 seconds

Low Battery

Beeping every second

UPS Fault

Beeping Continuously

Overload

Beeping twice per second

Parameter Re-settable

Voltage,Frequency,5 steps Charge current

 Environment

 Operation Temperature

0-40 degree C; 32-104 degree F

 Relative Humidity

0-95% non-condensing

 Audible Noise

Less than 55dBA (at 1M)

 Physical

 Wall Mounted Type(W*H*D)mm

 298*400*150

 Wall Mounted Type Net Weight (Kgs)

 14.8

 Safety Conformance

 Safety Standard

 

EN62040-1-1

 EMC

EN62040-2

 Marks

CE

*Mark: Specifications are subjected to change without prior notice (090728).