Converter ALP-80-160KVA
Features
- Adopting the DSP technology and IGBT component.
- The Galvanic Isolation in AC input and output
- Powerful overload and interference-resist ability
- Wild AC input range (145~315VAC),Wild frequency input range
- Special load protection makes UPS is fit for any type of the load.
- Startup without surge current
- Repair & Maintenance the whole day through Long-range dial
- The design of single PC control can improve the reliability and maintenance conveniently.
- The design of anthropomorphized operation makes the operation more safe and convenient.
- Perfect protection ensures the system can automatically cut off when the abnormal condition occurred.
- Intelligent communication function supports the MAGATEC, UPSilon2000 and Netagent.
- Approve EN50091-1,-2
Overview
The Vesta series provides comprehensive protection and high power density in small and economic package. Compared to traditional UPS towers of the same size, Vesta UPS is more compact and offers greater comprehensive power protection against surges and spikes. Equipped with a voltage stabilizer, this UPS will continue providing clean and stable power to connected equipment while its embedded microprocessor controller guarantees high reliability, perfect for any home or small office applicatio
|
KVA |
80 |
100 |
120 |
160 |
INPUT (RECTIFIER)
Input Voltage |
208V /220V / 380V / 400V /415V /440V /460V /480V / 600V |
Input Range |
+ / - 20% ( > +/- 20% is available upon request) |
Input Frequency |
50 / 60 Hz + / - 5Hz |
Power Walk In |
0% - 100% : 20 sec |
Efficiency |
> 98% |
Voltage Regulation |
+ / - 1% |
INVERTER |
Output Voltage |
208V /220V / 380V / 400V /415V /440V /460V, + / - 1 % |
Wave Form |
Sine Wave |
Output Power Factor |
0.8 |
Output Frequency
(Free Running) |
50 / 60 / 400Hz + / - 0.1 Hz |
Phase Shift Under 100%
Unbalance Load |
< 0.5° |
THD (Linear Load) |
< 2 % |
Overload |
<110% |
Continuous |
110 ¨C 125% |
15 minutes |
125 ¨C 150% |
10 minutes |
> 150% |
1 minute |
Efficiency (100% Load) |
94.5% |
94.5% |
95% |
95% |
OVERALL CHARACTERISTICS |
Overall Efficiency |
92.5% |
92.5% |
93% |
93% |
Maximum Heat
Dissipation (Kw) |
4.6 |
5.4 |
6.5 |
8.7 |
Height x Width x Depth (mm) |
1600 x 1100 x 800, |
Weight
(Kg, without battery) |
820 |
950 |
1180 |
1450 |
Audible Noise |
< 67 dBA (At 1 M) |
Temperature |
0 – 40℃ ( 32 – 104℉ ) |
Humidity |
0% - 90% (Non-Condensing) |
Altitude |
<1500 M Above Sea Level |
EN50091-1,-2 |
YES |
Short Circuit Pretection |
YES |
Lightning / EMC Filter |
MOV / Input&Output (FCC CLASS A) |
Galvanic Isolation |
Input&Output true Galvanic isolation |
LED,LCD,Buzzer |
YES |
Remote Control /
Communication Interface |
Monitoring 1~99 UPS simultaneously / Dry contact, RS232, RS485 |
*Different specifications required are available.